Downloads

Home »  Datasheets

DocumentsDate added

Order by : name | date | hits [ ascendent ]
file icon Floodline Remote Alarmhot!
20.09.2007
The Floodline Remote Alarm unit provides a visual and audible warning of a leak or even a system fault.

The Remote Alarm can be mounted anywhere within the building and is connected back to the main Floodline Control Panel.
Hits: 260
file icon Floodline System Accessorieshot!
20.09.2007
Junction Boxes, Warning Tags and Leader Cable are all essential accessories for our leak detection installations.
Hits: 285
file icon Floodline Plug and Play Autoconnect Systemhot!
20.09.2007
Andel’s tried and tested Floodline multi-zone leak detection systems are well known for being the most reliable, effective and easy to use.  The “Plug & Play Auto-Connect” system allows instant, foolproof connection for quick, no-hassle installation by any engineer, contractor or competent person.
Hits: 365
file icon Floodline Tundish/Overflow Sensorhot!
20.09.2007
The Floodline Tundish/Overflow sensor is designed to be attached to the overflow of a toilet cistern or other tank to provide an immediate automatic warning in the event of an overflow.

The sensor can be used singly, or in multiples, connected to any of the Floodline alarm panels.  Each sensor can be allocated its own zone, or they can be installed in groups with a number of sensors attached together to form one zone.
Hits: 351
file icon Floodline Pipe-in-Pipe Sensorhot!
20.09.2007
The Floodline Pipe-in-Pipe Sensor is based around a Point Sensor but designed for fitting into a female threaded socket provided at strategic points in the outer pipe.  Short stainless steel probes extend into the cavity, or annulus, created between the inner and outer pipes.  When liquid escapes into the cavity and contacts a sensor the alarm is activated.  Two types of device are available for water and oil (oil/any liquid).
Hits: 353
file icon Floodline Flexi-Pad Sensorhot!
20.09.2007
The Flexi-Pad Sensors have been specifically designed for laying in narrow voids (too small for point sensors) or wrapped around pipes at valves or joints where leaks are more likely to occur. The Flexi-Pad Sensor can be used singly, or in groups with a number of sensors being connected together to form one zone.
Hits: 340
file icon Floodline Oil Sensorhot!
20.09.2007
The Floodline Oil Sensor can be included as part of a larger water leak detection system or one or more can be used to provide a dedicated oil leak alarm system.  Oil Sensors are connected to a standard Floodline Control Panel giving visual and audible alarm features in addition to the facility for onward, remote, communications to BMS etc.
Hits: 383
file icon Floodline Point Sensorhot!
20.09.2007
The Floodline Point Sensor is a compact sensor for vertical or horizontal mounting.  Water touching its stainless steel probes activates the alarm.  Used with the stainless steel Floodline Guard Plate to give heavy duty physical protection and assist fixing and adjustment.
Hits: 390
file icon Floodline Multi-8 8 Zone Detection Cablehot!
20.09.2007
The unique “Multi-Zone” construction of the Multi-8 - 8 Zone water sensitive cable allows up to eight separately reporting detection zones to be provided from one length of cable.
Hits: 401
file icon Floodline Multi-4 4 Zone Detection Cablehot!
20.09.2007
Super Absorbent - High Sensitivity

Multi-4 - 4 Zone Detection Cable has been used for over ten years in areas where maximum leak detection sensitivity is essential.
Hits: 384
file icon Floodline Single Zone Tapehot!
20.09.2007
For high sensitivity applications where a more basic, low cost system is required.  The Single Zone Tape is a very strong, easy to install sensor.  The sensor can be wetted and dried any number of times.  The zones can be any length but the usual length is between 5 and 15m.
Hits: 405
file icon Floodline Groundhog Mk IIhot!
20.09.2007
The Floodline Groundhog Mk II is a self-contained, single-zone leak detection system which can be mounted vertically or horizontally.  It can be connected to any control/building management system that has the facility to accept volt-free contacts.

Additional Floodline Point Sensors or Leak Detection Tape can be slaved off the Groundhog.
Hits: 390
file icon Floodline Leak 1 Mk IIhot!
20.09.2007
The Floodline Leak 1.MkII is a self-contained single zone leak detection module specially designed for incorporation into other control/ alarm systems, air conditioning units and BMS etc.  The module can be used with all Floodline sensors.
Hits: 441
file icon Floodline 128 Control Panelhot!
20.09.2007
The 128 Multi-Zone System operates a network of leak detection cables and sensors up to a total of 128 zones.  A zone can be a single point or many metres of detection cable and the whole network is continuously monitored for leaks and continuity.  Zones are electrically isolated from each other and individually displayed so the system can accept and report any number of simultaneous or consecutive zone alarms.  An alarm in one zone has no effect on the normal monitoring of its neighbours or the rest of the system.
Hits: 384
file icon Floodline Multi-Zone Control Panelshot!
20.09.2007
The Multi-Zone Control Panel operates the network of leak detection zones.  A zone can be a single point or many metres long and the whole network is continuously monitored for leaks and continuity.  Zones are electrically isolated from each other and individually displayed so the system can accept and report any number of simultaneous or consecutive zone alarms - true multiple leak reporting - an alarm in one zone has no affect on the normal monitoring of its neighbours or the rest of the system.
Hits: 484
<< Start < Prev 1 2 Next > End >>
Results 1 - 15 of 17